Hydro-Control V

Hydro-Control V

Interfacing

Input/Output Modules:
6 Output Modules and 4 Input Modules
are provided as standard. These modules
are supplied for 110v, 24v DC or can be
customised to your specification.
Only the water valve must be connected.
All other outputs/inputs are optional and
can be connected as appropriate for each
configuration (Note: no connection to
material load cells are required).

RS232 Communication:
For reading and writing information
relating to recipe parameters, as well
as selecting active recipe.
Technical specification

Supply voltage:
24v DC, 30w for Hydro-Control V
and Hydro-Mix V. Higher power may
be required for powering valves and
other outputs.

Operating temperature range:
0 – 50ºC.
Keyboard:
Sheet keyboard with polyester overlay.
Graphic display:
120mm x 90mm 1/4 VGA display
with backlight.

Recipes:
Memory for 99 recipes.

Security:
Open access for operators; critical
operations protected by three levels
of pass codes.

Communications:
RS232 for connection to batch
computer or remote recipe module.
RS485 communications to
Hydronix sensor.
Sensor connection:
The Hydro-Mix V or Hydro-Probe Orbiter
Microwave Sensor is connected to the
Hydro-Control V by two pairs twisted
(4 cores total) screened (shielded) cable
with 22 AWG, 0.35mm2 conductors suitable
for up to 100m. Separate cable run to
any heavy equipment power cables.

Electromagnetic compatibility:
Meets the requirements of the
Electromagnetic Compatibility
Directive 89/336/EEC.

Detalii Tehnice Produse